Multi-Function Calibrator: Usage, Maintenance & Calibration Guide

Multi-function calibrators play a crucial role in ensuring the accuracy of various measuring instruments used in locomotives and other industrial equipment. These devices are essential for on-site inspections and maintenance, as they allow technicians to verify and calibrate field instruments to ensure their measurement accuracy meets required standards. A well-calibrated instrument is vital for maintaining operational efficiency and safety, as any miscalibration can lead to incorrect readings, misjudgments, and even potential hazards.

The SWP-CA102S/CA103 series multi-function calibrator is a reliable tool designed for accurate verification and calibration of digital and analog meters. It offers multiple functions, high precision, wide measurement range, and automation features, making it ideal for daily use in both laboratory and field settings. Proper usage and regular maintenance of this device are essential to maintain its performance and extend its lifespan.

The Role of a Multi-Function Calibrator

A multi-function calibrator serves as a reference standard for verifying the accuracy of various measuring instruments. It helps ensure that devices such as voltmeters, ammeters, and multimeters provide reliable readings. Without proper calibration, these instruments may give false readings, which could result in faulty decisions or even system failures. Therefore, using a multi-function calibrator is not just a technical requirement but also a safety necessity.

This type of calibrator is particularly useful for calibrating four-and-a-half digit digital meters and various grades of pointer-type voltmeters (e.g., 0.2 and 0.5 accuracy levels). Its versatility and high precision make it an indispensable tool for engineers and technicians working in fields where accuracy is critical.

How to Use a Multi-Function Calibrator

A multi-function calibrator typically includes components such as a power supply, signal source, high-power amplifier, and sampling feedback unit. To ensure its reliable operation, users must follow specific guidelines regarding environment, power connection, fuse replacement, preheating, and testing procedures.

Working Environment Requirements

Since the calibrator contains sensitive components like high-power amplifiers and temperature-sensitive references, it should be placed in a clean, dry, and well-ventilated area. Avoid placing it near heat sources or in areas with poor air circulation. The optimal operating temperature is between 0°C and 40°C, with a relative humidity of 80% or less. Using an air conditioning system can help maintain stable environmental conditions, which is crucial for accurate measurements.

Power Connection

To prevent electrical hazards, always use a three-wire grounded power cord. Before connecting the calibrator, double-check the power voltage and ensure the fuse is correctly installed. Connect the device to a reliable grounded socket. It's recommended to use a regulated power supply to protect the internal circuitry from voltage fluctuations.

Check and Replace Fuse

If the calibrator stops working, check the fuse. Follow these steps: 1. Turn off the power. 2. Open the fuse holder and gently remove the old fuse using a screwdriver. 3. Replace it with a new one of the correct specification (220V, 2A/250V). 4. Reinstall the fuse and ensure it is securely locked in place.

Instrument Preheating

As a precision instrument, the calibrator needs to be preheated before use. This allows internal components to reach thermal stability, ensuring accurate results. Typically, a 5-minute preheat is sufficient. If the device has been idle for a long time or in high-humidity environments, increase the preheating time to up to 30 minutes.

Verification/Calibration Test

Before performing any tests: - Do not exceed the calibrator’s output range. - Set the output switch to neutral and adjust the output to zero before connecting the device under test. - Use appropriate test leads based on the type of measurement (e.g., 1500V insulation strength for high voltage, 3A/mm² for current testing). - Always select the correct range before applying power to avoid damaging the instrument or causing personal injury. - When adjusting current output, avoid sudden changes and monitor the display closely. - Limit the time when using high-current outputs (e.g., 5A, 10A) near the upper limit to prevent damage.

Calibration and Verification of the Multi-Function Calibrator

Each multi-function calibrator comes with an absolute uncertainty indicator for one year after factory calibration. During daily use, you can perform basic adjustments following the manufacturer’s instructions. However, for more precise calibration, it is recommended to send the device to a certified calibration center periodically.

Determination of Maximum Allowable Error

The maximum allowable error is the primary criterion for determining whether an instrument meets its technical specifications. The calibration cycle is usually set to one year. The absolute uncertainty of the calibrator is used as the basis for checking if the device is out of tolerance. Once the uncertainty is known, a higher-level standard is selected for comparison, and the calibrator’s performance is tested accordingly.

Adjustment of Calibrator Indicators

The technical indicators of the calibrator reflect drift and environmental effects over time. Adjustments should be made only when the instrument is out of tolerance or close to it. Some experts recommend calibrating during routine checks to keep the instrument in optimal condition. The calibrator supports internal software self-calibration, allowing users to optimize its performance during each calibration cycle.

Verification Cycle and Process

The verification process assesses the calibrator’s ability to maintain its technical specifications over time. A one-year absolute uncertainty indicator ensures that factors like temperature, linearity, and load adjustment remain within acceptable limits. Regular verification is necessary to confirm that the device continues to meet its original performance standards. This involves checking stability, drift, and recalibrating if needed to ensure consistent and accurate results.