Detection method and sequence of industrial computer failure failure

1, check the three working conditions of the CPU

powered by

clock

Reset

2. Remove the BIOS and check if the 22-pin chip select signal has a transition.

3. Try changing the BIOS and check the line connected to the BIOS.

4, check ISA, PCI data lines, address lines (and AD), interrupts and other control lines (this can directly reflect the North and South Bridge problems)

5, check AGP, PCI, CPU block ground resistance to determine whether the North Bridge is normal

(A), power supply CPU core voltage

(1) no voltage

A, FET is broken, open or shorted

B, filter capacitor short circuit (electrolytic capacitor)

C, voltage IC has no output

No 12V power supply

Voltage IC is bad

Broken line

(2) low voltage

A, the CPU operating voltage related line has a slight short circuit

B, the FET is broken, and the output voltage is also low.

(3) High voltage

C, the feedback circuit has no effect

D, voltage IC output voltage is low

(2) VID0-4 (+5V voltage)

Voltage IC has no output

The exclusion resistance connected to the CPU base is bad

Broken line

(3) VTT 1.5V

(1) no voltage

Power supply field effect tube is broken

VTT1.5V has short circuit to ground

(2) Voltage level

FET power supply is not normal

Field effect tube is broken

(four) clock

(1) No clock

Open circuit between CPU socket and clock IC

Clock IC no output

Bad filter capacitor connected to the output (10 picofarads)

(2) Clock IC has no output

Is the power supply normal? 3.3V 2.8V 2.5V

All no output or half no output

Whether the crystal oscillator starts to vibrate 22 or not

(3) No output at all

Powered, IC is bad

No power supply, check the power supply related lines

(4) half of the output

IC is bad

Check for abnormal half of the power supply

(5) Reset

(1) No reset 1.5V

A, the reset voltage is low: the north bridge is broken

B, there is no voltage reset

North Bridge false welding or North Bridge without reset

The line connected to the North Bridge is disconnected

(2) Northbridge has no reset (see whether PCI, AGP, IDE are normal)

Reset: break line with North Bridge

No reset: check the reset generation circuit

300 Puff

300 Puffs Disposable ecig have a completely enclosed design, reducing the need for charging and replacing cartridges. The no-charge design also reduces the occurrence of faults. It is understood that with rechargeable e-cigarettes, each cartridge needs to be charged at least once and the battery efficiency is extremely low, while the design of disposable ecig can solve this problem very well.